Define a functional width-tolerance record Connect measurement conditions to both sides of the assembly window. Constrained interfaces Record: Buckle slot, guide, folder, fixture, seam or coverage point Project detail: ____________________ Confirm: Measure controlled physical parts Width stage Record: Before or after finishing, relaxed delivered roll and any conditioning Project detail: ____________________ Confirm: Name the acceptance stage Measurement setup Record: Gauge, contact shape, pressure, orientation and handling of curved tape Project detail: ____________________ Confirm: Demonstrate operator method Sampling positions Record: Roll selection, distance from ends, positions along each roll and reading count Project detail: ____________________ Confirm: Mark positions on inspection plan Functional limits Record: Nominal, minimum for coverage or grip and maximum for passage Project detail: ____________________ Confirm: Trial boundary samples in assembly Decision rule Record: Individual limits, treatment of average, invalid readings and recheck Project detail: ____________________ Confirm: Apply to recorded spread Tolerance values and sample frequency are project-defined. Report individual readings and spread; do not use an average to hide an out-of-limit section. Sinicwebbing — https://www.sinicwebbing.com